Glossary of historian and SCADA terms

48 terms used around industrial data, OPC UA, Modbus and battery storage, explained plainly for engineers and the people who work with them.

Acknowledged value
A value the historian has made durable, usually by writing it to a log on disk. Until a value is acknowledged it can be lost in a power cut; afterwards it should survive one.See also: Write-ahead log, fsync
Aggregate
A value calculated over an interval from raw samples: minimum, maximum, mean, count or a time-weighted average. Trends over long periods draw aggregates because there are more samples than pixels.See also: Interpolation, Envelope
Asset model
The plant described as areas, units and equipment, with each signal placed under the thing it measures. It lets people find "Inverter 3, active power" instead of a PLC address.See also: Tag
Basic256Sha256
An OPC UA security policy using RSA keys of up to 4,096 bits and SHA-256. Widely supported by controllers such as the Siemens S7-1500; newer AES-based policies are replacing it.See also: Security policy, OPC UA
BESS
Battery energy storage system. On the grid, usually containers of battery racks with a power conversion system, connected through a transformer and switchgear, providing trading and grid services. Read what to log on a battery site.See also: PCS, BMS, SoC
BMS
Battery management system. Monitors cell voltages and temperatures, state of charge and health, and protects the battery by limiting charge and discharge or opening contactors.See also: BESS, SoC, SoH
Calculated tag
A signal the historian computes from other signals, such as total site power or daily energy, and stores like any other.See also: Tag
Chunk
A block of compressed samples for one signal over a stretch of time. Historians store data in chunks so that reading a period decodes only the chunks it touches.See also: Compression
Compression
Reducing the space data takes. Lossless compression (such as delta encoding) keeps every value exactly; lossy compression (such as deadband or swinging door) discards values judged unimportant. A good historian says which was in force.See also: Deadband, Swinging door
Data historian
Software that collects time-stamped values from industrial equipment, stores them efficiently for years, and serves them for trends, reports and analysis. Read what an industrial data historian does.See also: Tag, Sample
Deadband
A rule that stores a new value only when it differs from the last stored value by more than a set amount. It saves a lot of space on slow signals and loses detail on fast ones.See also: Compression, Swinging door
DNP3
Distributed Network Protocol, a telemetry protocol common in North American utilities and some grid connections, with event buffering and time-stamped data.See also: IEC 60870-5-104
Envelope
The band between the minimum and maximum of each interval, drawn around the mean when a long period is shown. It keeps spikes visible that an average would hide.See also: Aggregate
FAT
Factory acceptance test. Testing a control system against its specification before it goes to site, often on a bench with simulated field devices.See also: SAT
fsync
The operating-system call that forces data written to a file onto the physical disk. How often a historian calls it sets how much it can lose in a power cut.See also: Write-ahead log, Acknowledged value
G99
The Great Britain engineering recommendation for connecting generation, including storage, to distribution networks. It sets protection, compliance testing and data requirements.
Gap marker
A record in the history that says data is missing from a point in time, and why: a lost connection, a restart, a full disk. Without one, a trend may draw a straight line across the outage.See also: Quality code, Interpolation
Grafana
An open-source dashboard tool. Historians often act as a Grafana data source so that dashboards can be built over the stored data.
HMI
Human-machine interface. The screens operators use to see and control a process; often running on a panel PC that can also host a historian.See also: SCADA, PLC
IEC 60870-5-104
A telecontrol protocol over TCP/IP used between substations, generation sites and network control centres, widely used in Europe for grid connections.See also: IEC 61850, DNP3
IEC 61850
A family of standards for substation automation, defining data models and protocols (MMS, GOOSE, sampled values) used by protection relays and bay controllers.See also: IEC 60870-5-104
Interpolation
Estimating a value between two stored samples, either as a straight line (linear) or by holding the last value (step). Useful for analysis, and misleading if applied across a gap.See also: Gap marker
Modbus TCP
A simple request-and-response protocol over Ethernet for reading and writing registers and coils, used by meters, relays, inverters and gateways. Read about logging Modbus TCP with Vault.See also: Register, Word order
Monitored item
In OPC UA, a single node the client has asked the server to watch. Servers limit how many they will handle; an S7-1500's limit depends on the CPU and firmware.See also: Subscription, OPC UA
NESO
The National Energy System Operator, which balances Great Britain's electricity system and procures services such as dynamic frequency response from batteries.See also: BESS
OPC UA
OPC Unified Architecture, a platform-independent standard for industrial data exchange with a browsable address space, subscriptions and built-in security. Read about logging OPC UA with Vault.See also: Subscription, Security policy, Monitored item
Parquet
An open, column-based file format for large tables. Analysis tools such as Python, DuckDB and Power BI read it quickly, which makes it a good export format for history.
PCS
Power conversion system: the inverter that converts between the battery's DC and the grid's AC and follows the site controller's power setpoint.See also: BESS
PLC
Programmable logic controller. The industrial computer that runs the control logic for a plant and often hosts the OPC UA or Modbus server a historian reads from.See also: HMI, SCADA
Publishing interval
In OPC UA, how often the server sends a subscription's changed values to the client. Separate from the sampling interval, which is how often the server checks each value.See also: Sampling interval, Subscription
Quality code
A status stored with each value saying whether it can be trusted: good, uncertain or bad, often with a reason such as a communication failure. A bad value should be shown as a gap, not a number.See also: Gap marker
Register
A 16-bit memory location in a Modbus device. Values larger than 16 bits span two or four registers, and devices disagree about their order.See also: Word order, Modbus TCP
Republish
An OPC UA service that asks the server to resend a notification the client missed, for example after a brief network drop.See also: Subscription
Sample
One stored value of one signal, with its timestamp and quality.See also: Tag, Quality code
Sampling interval
In OPC UA, how often the server checks a monitored item for a change. A value that changes and changes back between samples is never seen.See also: Publishing interval
SAT
Site acceptance test. Testing the installed system on site, with real equipment, before handover.See also: FAT
SCADA
Supervisory control and data acquisition. The system that gathers data from a site's controllers and lets operators supervise and control it. Many SCADA packages include a historian; many small sites have only short-term trends.See also: HMI, PLC
Security mode
In OPC UA, whether messages are unprotected (None), signed so they cannot be altered (Sign), or signed and encrypted (Sign & Encrypt).See also: Security policy
Security policy
The set of algorithms an OPC UA connection uses for signing and encryption, such as Basic256Sha256 or Aes256_Sha256_RsaPss.See also: Security mode, Basic256Sha256
SoC
State of charge: how full a battery is, as a percentage of its usable capacity.See also: SoH, BMS
SoH
State of health: a battery's remaining capacity compared with when it was new, used to track degradation against a warranty.See also: SoC, BMS
Sparkplug B
A specification for carrying industrial data over MQTT with defined topics, payloads and birth and death messages, popular for sending site data to cloud platforms.
Store-and-forward
Buffering data locally while a link to a central system is down, then sending it when the link returns, so the central record has no gap.
Subscription
In OPC UA, a group of monitored items whose changes the server sends to the client at the publishing interval, instead of the client polling each value.See also: Monitored item, Publishing interval
Swinging door
A lossy compression method that drops values lying close to a straight line between stored points. Efficient on smooth signals; it can hide short events.See also: Deadband, Compression
Tag
A named signal in a control system or historian, such as an inverter's active power. Many historians are licensed by the number of tags.See also: Sample, Asset model
Word order
The order in which a Modbus device places the 16-bit registers of a 32 or 64-bit value. The four common orders are ABCD, BADC, CDAB and DCBA; get it wrong and values are nonsense.See also: Register
Write-ahead log
A file a system appends every change to, and flushes to disk, before applying the change elsewhere. After a crash the log is replayed so nothing acknowledged is lost.See also: fsync, Acknowledged value

See Vault on your own plant